External input/output modules allow control units to be expanded with additional sensors and control elements. They ensure flexible device connectivity and reliable data collection and control in a variety of applications.

AIM600, AIM615 - 4-20 mA/RS485 Converters

AIM600, AIM615 - 4-20 mA/RS485 Converters

The AIM600 and AIM615 transducers are characterized primarily by high measurement accuracy provided by the 24-bit converter, as well as low quiescent current consumption, a supply voltage suitable for operation from a 12 V battery, galvanic isolation of the inputs from both the supply voltage and the RS485 communication line, and, last but not least, high operational reliability without any mechanical adjustment elements.

View
B3OK – ISCO Converter

B3OK – ISCO Converter

The B3OK converts the three binary outputs of ISCO devices to inputs for FIEDLER telemetry units (H1, H3, and others). It enables simple and secure connection of ISCO devices to data logging and control systems without the need for additional modules.

View
DV2 - Binary Input and Output Module

DV2 - Binary Input and Output Module

The DV2 external input/output module expands the number of binary inputs and relay outputs. Up to two DV2 I/O units can be connected to the H3 station via the RS485 interface. Up to 10 DV2 modules can be connected to the H3 and H7 series units.

View
GX200 - Current Loop Galvanic Isolation Module

GX200 - Current Loop Galvanic Isolation Module

A galvanic isolation module for 0–20 mA and 4–20 mA current signals that does not require an external power supply, designed for two-wire transducers.

View
H520-B - Level Display Module

H520-B - Level Display Module

The H520-B display module is designed to provide an approximate indication of the liquid level. The module does not contain a liquid level sensor; it merely displays the liquid level data received from a connected control system via the RS485 bus.

View
MAV421, MAV422 - Modules with 4–20 mA Output

MAV421, MAV422 - Modules with 4–20 mA Output

The MAV421 and MAV422 external modules are RS485 converters operating under the FINET protocol, providing galvanically isolated active current outputs of 4–20 mA or 0–20 mA. The MAV421 module has one current output (I1), while the MAV422 module has two current outputs (I1 and I2).

View
OPTO3 - Pulse Signal Splitter

OPTO3 - Pulse Signal Splitter

The OPTO3 galvanically isolated pulse splitter has one pulse input for connecting a signal from a water meter or electric meter sensor and three mutually galvanically isolated pulse outputs.

View
PO2D - Combined Surge Protection

PO2D - Combined Surge Protection

This is a combined two-stage surge protection device for a two-wire signal line and a power line.

View