FIEDLER > Level measurement > Radar level meters > Non-contact radar level meters > VEGAPULS C 21 – Radar Level Transmitter
Non-contact radar level meters

VEGAPULS C 21 – Radar Level Transmitter

The VEGAPULS C 21 is a highly accurate radar level sensor designed as a superior replacement for ultrasonic sensors, primarily in the water supply industry and for measuring the volume of discharged wastewater. The sensor’s flood-resistant housing with an IP68 rating ensures long-term, maintenance-free operation.

  • Very high measurement accuracy of up to ±2 mm
  • Virtually zero temperature dependence
  • Measurements are not affected by pressure or dust
  • Accurate measurements even when foam is present on the surface
  • Zero dead zone below the sensor (with slightly increased measurement inaccuracy in the range up to 25 cm below the sensor)
  • A narrow 8° beam angle allows the sensor to be used even in confined spaces such as underground sumps
  • Measurements are unaffected by ambient noise generated during hopper filling
  • User-friendly limit settings without the need to fill and empty the hopper
  • No maintenance required (condensation or dust buildup on the sensor does not interfere with operation)
  • Cost-effective radar sensor as a technologically advanced replacement for ultrasonic sensors
  • 4–20 mA two-wire connection to H1, H2, H3, and H7 stations, as well as Q2 stations, even in battery-powered systems operating in switched mode
  • A sensor with a Modbus or SDI-12 digital output is available upon request for an additional charge

Description

The sensor transmits a frequency-modulated radar signal via the antenna system. The signal frequency varies in a sawtooth pattern. The transmitted signal, after being reflected by the medium, is received by the antenna as an echo with a changed frequency. The change in frequency is proportional to the measured distance.

Applications

  • Non-contact level measurement of bulk solids.
  • Measurement of all types of liquids, even under high pressure or at extreme temperatures
  • Suitable for monitoring not only wastewater tanks but also tanks containing thinners, solvents, or other corrosive liquids
  • Suitable for applications with the highest hygiene requirements

Technical specifications

Technical Specifications VEGAPULS C 11 - Radar Level Transmitter
Max. measuring range 15 m (recommended up to 10 m)
Process connection threaded connection (G1½ / G1, 1½ NPT / 1 NPT, R1½ / R1)
Process temperature -40...60 °C
Process pressure -1...3 bar (-100...300 kPa)
Accuracy ±2 mm
Frequency 80 GHz
Beam angle 8°
Wetted parts PVDF
Seals FKM
Protection rating IP66/IP68 (3 bar)
Output signal 4...20 mA / HART (Modbus or SDI-12)
Ambient temperature -40...+60 °C
Supply voltage 12...36 V DC
Rise time <15 s at a current of ≤ 3.6 mA
PVC Connection Cable length 5 m, diameter 8 mm
Connection integrated Bluetooth 5.0 module for easy configuration via a mobile app (typical range 25 m)

Non-binding inquiry

VEGAPULS C 21 – Radar Level Transmitter



    Contact

    Have a project or a question?

    Free consultation - our specialists will help you choose the right solution for your project.