4310 Precise ultrasonic anemometer

- Highly accurate ultrasonic anemometer with RS485 output compatible with FIEDLER recording units
- Robust design of the device without moving parts
- High measurement accuracy given by optimized aerodynamic design of ultrasonic sensors
- Supply voltage in a wide range of 9 to 36 VDC
- Variant design with outputs RS422, 0..10V, 4-20 mA, CAN, ...
Optimized design
The design of the mechanical design of the ultrasonic anemometer was also made with the help of SW simulation. As a result, turbulence occurring on ultrasonic transducers was minimized.

Reducing turbulence to a minimum resulted in a maximum increase in the accuracy of wind speed and direction measurements.
Application
- Professional weather stations
- Intelligent building management (heating, clinization, ventilation, ...)
- Industrial buildings and security of building structures
- Science and research - environmental monitoring
Technical parameters
| Parameetrs | Value |
WIND SPEED MEASUREMENT | |
| Measuring range: | 0..75 m/s (0..85 m/s; 0..90 m/s) |
| Measurement accuracy: | ±0,1 m/s for v≤5 m/s; ±1,5% from the measured value for v>5 m/s |
| Starting threshold: | 0,1 m/s |
| Resolution: | 0,1 m/s or 0,01 m/s |
MEASUREMENT OF WIND DIRECTION | |
| Measuring range: | 0..359° |
| Measurement accuracy: | ±1° |
| Resolution: | 1° or 0,1° |
AIR TEMPERATURE MEASUREMENT | |
| Measuring range: | -55..+70 °C |
| Measurement accuracy: | 0,5 K |
| Resolution: | 0,1K or 0,01K |
DATA OUTPUT | |
| Serial communication: | RS422 full duplex / RS485 half duplex (1200..115200 Baud) |
| Analog output: | 0/4..20 mA nebo 0..10V (16 bit) |
| Protocol: | ASCII / MODBUS / NMEA |
OWER SUPPLY AND DIMENSIONS | |
| Power voltage: | 9..36 V DC / 100 mA; 24 V DC (+15%; -50%) |
| Dimensions: | diameter 220mm, height 221 mm |
| Material: | stainless steel V4A |
OTHER PARAMETERS | |
| Weight | 1,4 kg |
| Cover: | IP67 |
| Operating temperature range: | -55..+70 °C (with additional sensor body heating) |
Documentation:
Download: